Cleaning the spray arms

Machine care

Cleaning the spray arms

From time to time, particles may become trapped in the spray arm jets. The spray arms should be inspected and cleaned every 4 - 6 months.

Remove the spray arms as follows:

^Unscrew the upper spray arm.

^Unscrew the middle spray arm (under the upper basket) clockwise at the knurled nut.

The knurled nut has a left hand thread. To unscrew the spray arm turn the nut and the spray arm to the right.

^Remove the lower basket. Pull the lower spray arm firmly upwards to remove.

^Use a sharp pointed object to push particles into the spray arm jets and rinse thoroughly under running water.

^Open the cap of the lower spray arm, by turning it clockwise, to rinse out particles.

^After cleaning close the cap tightly.

^After replacing the spray arms check that they rotate freely.