Machine care
Cleaning the spray arms
From time to time, particles may become trapped in the spray arm jets. The spray arms should be inspected and cleaned every 4 - 6 months.
Remove the spray arms as follows:
^Unscrew the upper spray arm.
^Unscrew the middle spray arm (under the upper basket) clockwise at the knurled nut.
The knurled nut has a left hand thread. To unscrew the spray arm turn the nut and the spray arm to the right.
^Remove the lower basket. Pull the lower spray arm firmly upwards to remove.
^Use a sharp pointed object to push particles into the spray arm jets and rinse thoroughly under running water.
^Open the cap of the lower spray arm, by turning it clockwise, to rinse out particles.
^After cleaning close the cap tightly.
^After replacing the spray arms check that they rotate freely.