Building in the appliance

Building in the appliance

*The appliance depth is increased by approx. 35 mm for appliances with wall spacers fitted.

￿Top box

￿Appliance

￿Housing unit

￿Wall

The appliance can be installed in a kitchen run. To match the height of the rest of the kitchen, the appliance can be fitted with a suitable top box ￿.

A ventilation gap of at least 50 mm depth must be allowed for behind the appliance across the entire width of the top box for air to circulate.

The cross section of the air outlet under the room ceiling must be at least

300 cm2 to ensure that air can circulate without hindrance. Otherwise the

appliance has to work harder, resulting in an increase in electricity consumption.

The air inlet and outlet must not be covered or blocked in any way. They should be dusted on a regular basis.

When built into a kitchen run (max. depth 580 mm) the appliance can be installed directly next to a kitchen furniture housing unit. The appliance door will protrude in front of furniture fronts at the sides by 34 mm* and by 55 mm* in the middle of the door. This enables the doors to be opened and shut without being obstructed.

When installed next to a wall ￿ a distance of approx. 55 mm must be maintained on the hinge side between the wall ￿ and the appliance ￿, so that the doors and the handles have sufficient space for opening.

49