Electrical connection

Electrical connection

Electrical connections should be made by a qualified electrician in accordance with all local and na- tional ordinances.

Note to the installer:

Please leave these instructions with the consumer.

Power supply:

Please check the dataplate for 240 VAC; 60 Hz or

208 VAC; 60 Hz

Caution:

Disconnect the appliance from the main power supply before servic- ing. To reduce the risk of electric shock, make sure that the ap- pliance is properly grounded after installation.

WARNING:

THIS APPLIANCE MUST BE GROUNDED

For CDN only

The appliances are provided with 3 ter- minal leads: 1 black wire, 1 red wire and 1 green wire which have to be con- nected to a separate overcurrent pro- tection device (fusebox).

All hot wires (black and red) have to be fused individually before connecting them to the main power supply leads.

Use 15 Amp fuses for appliances rated 240 VAC.

Connect black terminal wire to L1 (black) and red terminal wire to L 2 (red) . The green terminal wire (ground) has to be connected directly to the equivalent colored power supply lead.

All connections must be done in a proper way.

ALSO SEE THE WIRING DIAGRAM PROVIDED WITH THE APPLIANCE.

For USA only

The appliance is provided with 3 termi- nal leads, 1 black wire (L 1), 1 red wire (L 2) and 1 green wire (GND) which must be connected to a dedicated line, inside of an approved junction box. Connect the black wire to L 1, the red wire to L 2 and the green wire to GND.

ALSO SEE THE WIRING DIAGRAM PROVIDED WITH THE APPLIANCE.