Settings - Supervisor level
Cleaning the airways | Cleaning the lint filters |
The lint filters must be cleaned after every drying cycle. Additionally the indicator "Clean out airways" lights once a certain level of lint is collected. The user can decide at which level of lint collection the indicator should come on.
off
"Clean out airways" does not light up
heavy
"Clean out airways" shows only when large amount of lint is collected.
normal Factory default
light
"Clean out airways" shows even when a small amount of lint is collected.
The display "Clean filter" reminds the user to clean the lint filter. The user can decide after how many operating hours this reminder should show.
The setting depends on the amount of lint. Adjust the interval depending on the use of the dryer.
Factory default: after 20 hours.
Display the residual moisture as a percentage
In addition to the drying levels, the residual moisture as a % can be displayed in the program cycle.
Factory default: without percent indication
Cool air free
If the dryer is used with a coin mechanism, the program "Cool air" can be provided free of charge.
free (factory default)