Miele T9800HRT service manual Manual Calibration

Models: T9800HRT

1 44
Download 44 pages 25.88 Kb
Page 24
Image 24

MANUAL CALIBRATION

Address

Description

Default

Minimum

Maximum

 

 

 

Value

Value

Value

 

 

 

 

 

 

 

P0 PWM MIN

PWM value at min speed (0.5

34

1

 

111

SPD

mph/0.8kph)

 

 

 

 

 

 

 

 

 

 

 

P1 PWM 1/2

PWM value at 1/2 max speed (6.0

176

110

251

MAX

mph/10.0kph)

 

 

 

 

 

 

 

 

 

 

 

P2 PWM MAX

PWM value at max speed (12.0

341

249

486

SPD

mph/20.0kph)

 

 

 

 

 

 

 

 

 

 

 

P4 ELEVATION

Value at zero or minimum elevation

40

27

 

71

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

P5 ELEVATION

Value at maximum elevation

218

71

 

228

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

P13 ELV

 

 

YES

 

 

 

DIRECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

P19 MAGNET

 

 

26

1

 

48

COUNT

 

 

 

 

 

 

 

 

 

 

 

 

 

P20 EFF

 

 

67.8

 

 

 

DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

P21 PWM

 

 

30

1

 

~

START SPD

 

 

 

 

 

 

 

 

 

 

 

 

 

P29 RAMP TIME

 

 

30

12

 

40

 

 

 

 

 

 

 

EXIT

Exits mode

 

 

 

 

Remarks:

 

 

 

 

 

 

Do not change the product below parameter , or it may cause malfunction.

 

 

 

 

 

 

 

 

Address

 

Default Value

 

 

 

 

 

 

 

 

 

 

P13 ELV DIRECTION

 

YES

 

 

 

 

 

 

 

 

 

 

 

P19 MAGNET COUNT

 

26

 

 

 

 

 

 

 

 

 

 

 

P20 EFF DIAMETER

 

67.8

 

 

 

 

 

 

 

 

 

 

 

P29 RAMP TIME

 

30

 

 

 

 

 

 

 

 

 

 

24

Page 24