OPERATION ERRORS

E16 – Stuck key error

OVERVIEW

If a key press is detected for more than 45 seconds a stuck key error is flagged. This error is primarily caused by a faulty keypad but could be caused by other issues (object on the keypad).

CORRECTIVE ACTION

Reset system power. If error re-occurs replace the keypad with a known good keypad. If error still occurs replace console PCB with known good console PCB.

E18 – Safety switch test failure

OVERVIEW

If the actual speed exceeds limit set for safety switch test a safety switch test failure error occurs..

CORRECTIVE ACTION

Re-calibrate system as listed in system calibration section of this document and re-run safety switch test. If system still fails safety switch test run speed feedback issue and speed control issue tests in the corrective action procedures section of this document.

E19 – NOVRAM Failure

OVERVIEW

If the values stored in non-volatile memory are out of limits or do not match the safety check value stored in non-volatile memory a NOVRAM failure occurs. The system attempts to re- initialize the non-volatile memory three times and if the NOVRAM check fails all three attempts a NOVRAM failure error (E19) is called.

CORRECTIVE ACTION

An E-19 error indicates the NOVRAM has critically failed and needs to be replaced. If an E19 error occurs the console should be reprogrammed with the current software version and the power should be toggled. If this does not clear the E-19 error the console PCB will need to be returned to DCI for repair.

44

Page 44
Image 44
Miele T9800HRT service manual Operation Errors