Installing the dryer vent

Calculation example

A

Wall pipe, with grill insert

 

 

= 1 x 3.8 m Comparative duct

= 3.8 m

 

length

 

B/D

2 elbows, 90°

 

 

= 2 x 0.8 m Comparative duct

= 1.6 m

 

length

 

C

0.5 m plastic piping

 

 

= 0.5 x 1 m Comparative duct

= 0.5 m

 

length

 

E

Left side vent opening

 

 

= 1 m Comparative duct length

= 1.0 m

 

Total duct length

= 6.9 m

Result: Total duct length is less than 20 m (as per Table II). Therefore a pipe diameter of 100 mm is adequate.

Rear or side exhaust connection

At the rear

Dryer is delivered with this connection open.

￿Install the vent duct as described on the following pages.

Sideways to left or right

￿Unscrew the cover (counterclockwise).

￿Refit the cover securely in the rear vent outlet.

￿Install the vent duct as described on the following pages.