Installing the dryer vent
Calculation example
A | Wall pipe, with grill insert |
|
| = 1 x 3.8 m Comparative duct | = 3.8 m |
| length |
|
B/D | 2 elbows, 90° |
|
| = 2 x 0.8 m Comparative duct | = 1.6 m |
| length |
|
C | 0.5 m plastic piping |
|
| = 0.5 x 1 m Comparative duct | = 0.5 m |
| length |
|
E | Left side vent opening |
|
| = 1 m Comparative duct length | = 1.0 m |
| Total duct length | = 6.9 m |
Result: Total duct length is less than 20 m (as per Table II). Therefore a pipe diameter of 100 mm is adequate.
Rear or side exhaust connection
At the rear
Dryer is delivered with this connection open.
Install the vent duct as described on the following pages.
Sideways to left or right
Unscrew the cover (counterclockwise).
Refit the cover securely in the rear vent outlet.
Install the vent duct as described on the following pages.
36