Extending the cooling downtime
The cooling down phase which takes
place before the end of a programme
can be lengthened if required. This
makes the garments easier to handle.
The cooling down time
can be extended by 5 minutes or 10
minutes.
is not available for timed drying,
smoothing or handcare programmes.
Follow steps Ato Fto programme
and store in memory.
Before you begin, first ensure that:
The tumble dryer is switched off.
The door is closed.
APress the Start/Stop button and keep
it pressed in whilst carrying out steps
B-C.
BPress the I-On/0-Off button in.
Wait until the indicator light for the
Start/Stop button lights up
constantly ...
C. . . and then release the Start/Stop
button.
DPress the Low temperature button
three times.
The Low temperature indicator light
will briefly flash on and off seven
times.
Pand 0(default setting) will flash
alternately in the display.
The number which appears alternately
in the display with Pmeans:
0Default setting
iThe cooling down time will be five
minutes longer.
(The Automatic indicator light will
also flash once).
2The cooling down time will be ten
minutes longer.
(The Automatic indicator light will
also flash twice).
EPressing the Start/Stop button
switches from one to the other.
FSwitch the dryer off with the
I-On/0-Off button.
The setting you have selected is now
stored in memory. You can change it
again at any time.
Programmable functions
48