Configuring the Switch

3-10

3
CLI – Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions
Use the Switch Information page to display hardware/firmware version numbers for
the main board and management software, as well as the power status of the system.
Field Attributes
Main Board
Serial Number – The serial number of the switch.
Number of Ports – Number of built-in RJ-45 ports and SFP slots.
Hardware Version – Hardware version of the main board.
Internal Power Status – Displays the status of the internal power supply.
Redundant Power Status* – Displays the status of the redundant power supply.
* CLI only.
Management Software
Loader Version – Version number of loader code.
Boot-ROM Version – Version of Power-On Self-Test (POST) and boot code.
Operation Code Version – Version number of runtime code.
Role – Shows that this switch is operating as Master (i.e., operating stand-alone).
Console(config)#hostname R&D 5 4-25
Console(config)#snmp-server location WC 9 4-113
Console(config)#snmp-server contact Ted 4-113
Console(config)#exit
Console#show system 4-60
System description: 24-Port 10/100/1000 ports + 4 Gigabit SFP Combo ports
L2+ Management Switch
System OID string: 1.3.6.1.4.1.835.6.10.51
System information
System Up time: 0 days, 2 hours, 4 minutes, and 7.13 seconds
System Name : R&D 5
System Location : WC 9
System Contact : Ted
MAC address : 00-30-f1-47-58-3a
Web server : enable
Web server port : 80
Web secure server : enable
Web secure server port : 443
Telnet server : enable
Telnet port : 23
POST result
DUMMY Test 1.................PASS
UART LOOP BACK Test..........PASS
DRAM Test....................PASS
Timer Test...................PASS
PCI Device 1 Test............PASS
Switch Int Loopback test.....PASS
Crossbar Int Loopback Test...PASS
Done All Pass.
Console#