Appendix C: SPECIFICATIONS

Net Safety Monitoring Inc.

Appendix C: SPECIFICATIONS

SENSOR SPECIFICATIONS

 

SENSOR ELEMENT

 

Oxygen O2 (ST1400)

 

 

 

 

 

 

Operating Temperature Range

 

-20°C to +50°C (-4F to +122F)

 

 

 

Range of Detection

 

0 to 25%

 

 

 

 

 

 

Response Time

 

<15 seconds to T95

 

 

 

 

 

 

Span Drift

 

<5% of signal loss / year

 

 

 

 

 

 

Enclosure Material

 

Anodized / powder coated aluminum (optional stainless steel)

 

 

 

Certifications

 

CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups C and D.

 

 

 

IEC Rating Ex d IIB T6 NEMA 3R (Class 1, Zone 1, Grp IIB T6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

0.5 Kg (1.0 lb)

 

 

 

 

 

CONTROLLER SPECIFICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

MILLENNIUM

ANALOG

 

ANALOG/RELAY

 

ANALOG/DIGITAL

 

 

 

 

 

 

 

 

 

 

Operating Temperature Range

 

 

 

-20°C to +50°C (-4F to +122F)

 

 

 

 

 

 

 

 

 

 

Power Consumption @ 24 V dc

Nom 68 mA / 1.63 W

 

Nom 75 mA / 2.0 W

 

Nominal 125 mA/3.01 W

 

 

Max 90 mA / 2.16 W

 

Max 108 mA / 2.6 W

 

Maximum 155mA/3.73 W

 

 

 

 

 

 

 

 

 

 

Humidity Range

 

 

0 to 99% relative humidity, non-condensing

 

 

 

 

 

 

 

 

 

 

 

Operating Voltage Range

 

 

 

10.5 to 32.0 V dc

 

 

 

 

 

 

 

Enclosure Material

 

Powder coated Copper Free Cast Aluminum (optional stainless steel)

 

 

 

 

Certifications

CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups B, C and D. NEMA 4X.

 

 

IEC Rating Ex d IIB+H2 T5

 

 

 

 

 

 

 

Note: With any Type 4 enclosure (electronics only-sensor remotely mounted in Class I, Division 1 area with seals between

 

 

sensor and electronics), CSA and NRTL/C certified for hazardous locations, Class 1, Division 2, Groups A, B, C and D.

 

 

 

 

 

 

 

 

 

Weight

3.2 Kg (7.0 lb)

 

 

 

 

 

 

 

 

 

Outputs

- 4 to 20 mA - Into a maximum loop impedance of 800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc. Isolated or non-isolated loop supply.

 

 

- Premium version - Form C contacts rated 5 Amps at 30 V dc / 250 V ac. Selectable energized / de-energized, latching/non-latching configurable low

 

 

and high alarms. Fault relay is factory set as energized, non-latching and cannot be modified.

 

 

 

 

Low Power Version - Form A contacts rated.2.5 Amps at 60 V ac/dc. Selectable energized / de-energized, latching/non-latching configurable low and

 

 

high alarms. Fault relay is factory set as energized, non-latching and cannot be modified.

 

 

 

 

- Digital RS 485 Modbus RTU Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 