.A complete Parts List is available at www.MillerWelds.com

4-3. Duty Cycle And Overheating

For Units Connected to a 120 Volt Circuit or a 240 Volt Circuit:

35% Duty Cycle At 27 amperes, 92 volts dc

35% duty cycle

3-1/2 Minutes Cutting

6-1/2 Minutes Resting

Overheating

Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, Temperature trouble light goes On, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty cycle before cutting or gouging.

YExceeding duty cycle can damage unit and void warranty.

A

0

 

 

15

 

OR

Minutes

Reduce Duty Cycle

sduty1 5/95 / Ref. 80503-A

4-4. Power Source Dimensions And Weight

Dimensions And Weight

18 lb (8.2 kg) including torch

5-1/2 in

(140 mm)

9 in

(229 mm)

YDo not move or operate unit where it could tip.

13-1/8 in

(333 mm)

loc_2 3/96 - Ref. 804 503-A

4-5. Torch Dimensions And Weight

 

8-3/8 in

1 in

(213 mm)

(25 mm)

3.0 lb (1.4 kg)

1-3/8 in

(35 mm)

 

Ref. 802 877

OM-225 216 Page 10

Page 14
Image 14