4-10. Connecting 1-Phase Input Power For 240 VAC
1
YInstallation must meet all National and Local Codes − have only qualified persons make this installation.
5
7
4
6
L1
L2
2
3
=GND/PE Earth Ground
1
YDisconnect and lockout/tagout input power before connecting input conductors from unit.
YAlways connect green or green/ yellow conductor to supply grounding terminal first, and never to a line terminal.
1Black And White Input Conductor (L1 And L2)
2Green Or Green/Yellow Grounding Conductor
3Input Power Cord.
4Disconnect Device (switch shown in the OFF position)
5Disconnect Device Grounding Terminal
6Disconnect Device Line Terminals
Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.
Connect input conductors L1 and L2 to disconnect device line terminals.
8 |
|
L2 | L1 |
240 VAC, 1
7
Select type and size of
8Receptacle (NEMA
Close and secure door on disconnect device. Remove lockout/tagout device, and place switch in the On position.