Miller Electric Big Blue 400 KX manual Mounting Welding Generator

Models: Big Blue 400 KX

1 72
Download 72 pages 99 b
Page 23
Image 23

5-2. Mounting Welding Generator

Y Do not weld on base. Weld-

 

ing on base can cause fuel

 

tank fire or explosion. Weld

 

only on the four mounting

Supporting The Unit

brackets or bolt unit down.

Do not mount unit by sup-

Y

 

porting the base only at the

 

four mounting brackets.

 

Use cross-supports to ade-

2

quately support unit and pre-

 

vent damage to base.

Mounting Surface:

OR

1

Inadequate support.

YDo not use flexible mounts.

1

1Cross-Supports

2Mounting Brackets (Supplied)

Mount unit on flat surface or use cross-supports to support base. Secure unit with mounting brack- ets.

31/2 in Bolt And Washer (Minimum − Not Supplied)

43/8-16 x 1 in Screws (Supplied)

To Bolt Unit In Place:

Remove hardware securing the four mounting brackets to the base. Reverse brackets and reattach to base with original hardware.

Using Mounting Brackets

Mount unit to truck or trailer with 1/2

in (12 mm) or larger hardware (not

 

 

supplied).

 

To Weld Unit In Place:

 

Weld unit to truck or trailer only at

 

the four mounting brackets.

 

2

Welding Unit In Place

Bolting Unit In Place

3

2

4

Tools Needed: 9/16 in

install3 6/05 803 274 / 200 864-A / 803 562

OM-4423 Page 17

Page 23
Image 23
Miller Electric Big Blue 400 KX manual Mounting Welding Generator