Miller Electric Big Blue 400 KX manual Check for obstructed throttle solenoid

Models: Big Blue 400 KX

1 72
Download 72 pages 99 b
Page 47
Image 47

Trouble

Remedy

 

 

Battery discharges between uses.

Turn Engine Control switch off when unit is not running.

 

 

 

Clean top of battery with baking soda and water solution; rinse with clear water.

 

 

 

Recharge or replace battery if necessary.

 

 

 

Periodically recharge battery (approximately every 3 months).

 

 

Engine idles, but does not come up to

Have Factory Authorized Service Agent check idle module PC5 and current transformer CT1.

weld speed (units with idle option only).

 

 

 

 

Check for obstructed throttle solenoid.

 

 

Engine does not run at idle speed

Check for obstructed throttle solenoid.

(units with idle option only).

 

 

 

 

Have Factory Authorized Service Agent check idle module PC5, and control relay CR4.

 

 

Engine uses oil during run-in period;

Dry engine according to run-in procedure (see Section 10).

wetstacking occurs.

 

 

 

OM-4423 Page 41

Page 47
Image 47
Miller Electric Big Blue 400 KX manual Check for obstructed throttle solenoid