Miller Electric Troubleshooting Guide for Miller Big Blue 400 Welding System

Models: Big Blue 400 KX

1 72
Download 72 pages 99 b
Page 45
Image 45

8-11. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

Also see Voltmeter/Ammeter help displays to assist in troubleshooting weld problems (see

 

 

 

 

 

 

 

Section 8-10).

A. Welding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

 

 

 

 

 

 

 

 

Remedy

 

 

No weld output; generator power output

Place Process/Contactor switch in a Weld Terminals Always On position, or place switch in a Remote

okay at ac receptacles.

 

 

 

 

 

 

On/Off Switch Required position and turn remote contactor on (see Section 6-3).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset circuit breaker CB8 (see Section 8-8). Check for faulty remote device connected to RC14.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check and secure connections to Remote Control receptacle RC14 (see Section 5-9).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Voltmeter/Ammeter help displays (see Section 8-10).

 

 

No weld output, or generator power out-

Disconnect equipment from generator power receptacles during start-up.

put at ac receptacles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset circuit breaker CB3. (see Section 8-8).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check fuse F1, and replace if open (see Section 8-8). If F1 is open, have Factory Authorized Service

 

 

 

 

 

 

 

 

 

 

 

 

 

Agent check the voltage regulator module PC3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Voltmeter/Ammeter help displays (see Section 8-10).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, voltage regulator module PC3, and

 

 

 

 

 

 

 

 

 

 

 

 

 

field excitation circuit.

 

 

 

 

 

 

 

 

Erratic weld output.

 

 

 

 

 

 

Check and tighten connections inside and outside unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Be sure connection to work piece is clean and tight.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Use dry, properly stored electrodes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove excessive coils from weld cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings.

 

 

 

 

 

 

 

 

High weld output.

 

 

 

 

 

 

Have Factory Authorized Service Agent check main control module PC1 and hall device HD1.

 

 

 

 

 

 

 

 

Low weld output.

 

 

 

 

 

 

Check engine speed, and adjust if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check fuse F1, and replace if open (see Section 8-8). If F1 is open, have Factory Authorized Service

 

 

 

 

 

 

 

 

 

 

 

 

 

Agent check the rotor.

 

 

 

 

 

 

 

 

Low open-circuit voltage.

 

 

 

 

 

 

Check engine speed, and adjust if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check main control module PC1, voltage regulator module PC3,

 

 

 

 

 

 

 

 

 

 

 

 

 

and main rectifier.

 

 

No remote fine amperage control.

Repair or replace remote control device.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check and secure connections to Remote Amperage Adjust receptacle RC14 (see Section 5-9).

 

 

No 24 volt ac output at Remote recep-

Reset circuit breaker CB8 (24 volt) (see Section 8-8).

tacle RC14.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Standard Generator Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

 

 

 

 

 

 

 

 

 

Remedy

 

 

No generator power output at ac recep-

Reset receptacle circuit breakers (see Section 7-1).

tacles; weld output okay.

 

 

 

 

 

 

 

 

 

 

 

 

 

No generator power or weld output.

Disconnect equipment from generator power receptacles during start-up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OM-4423 Page 39

Page 45
Image 45
Miller Electric Big Blue 400 KX manual Troubleshooting, Welding, Standard Generator Power