SECTION 7 − OPERATING AUXILIARY EQUIPMENT

7-1. 110 Volt Receptacles

34

2

1

Ref. 217 358-B

1110/55V 32 A AC Receptalce RC11

2110/55V 16A AC Receptacle RC12

Receptacles RC11 and RC12 supply 60 Hz single-phase power at weld/power speed.

Maximum output from RC11 is 3.5 kVA/kW. Maximum output from RC12 is 1.8 kVa/kW.

Maximum combined output of RC11 and RC 12 is 4.4 kVa/kW.

3 Circuit Breaker CB6

4 Circuit Breaker CB5

CB6 protects RC12 from overload. If a cir- cuit breaker opens, the receptacle does not work. Press button to reset breaker.

Circuit breaker CB5 protects receptacle RC11 and the generator winding from over- load. If CB5 opens, the receptacles do not work. Place CB5 switch in On position to reset circuit breaker.

.If a circuit breaker continues to open,

contact Factory Authorized Service Agent.

.Generator power decreases as weld output increases.