5-8. Selecting Weld Cable Sizes*

 

 

 

 

 

Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit

 

 

 

 

 

 

 

 

 

 

 

 

Not Exceeding***

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 ft (30 m) or Less

150 ft

200 ft

250 ft

300 ft

 

350 ft

400 ft

 

 

 

 

 

(45 m)

(60 m)

(70 m)

(90 m)

 

(105 m)

(120 m)

 

Weld Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminals

 

 

 

 

 

 

 

 

 

 

Y Stop engine before

Welding

10 − 60%

60 − 100%

 

 

 

 

 

 

 

connecting to weld out-

Duty

Duty

 

10 − 100% Duty Cycle

 

 

put terminals.

Amperes

 

 

 

Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YDo not use worn, dam- aged, undersized, or poorly spliced cables.

100

4 (20)

4 (20)

4 (20)

3 (30)

2 (35)

1 (50)

1/0 (60)

1/0 (60)

 

 

 

 

 

 

 

 

 

 

150

3 (30)

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

3/0 (95)

 

 

 

 

 

 

 

 

 

 

200

3 (30)

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

4/0 (120)

 

 

 

 

 

 

 

 

 

 

250

2 (35)

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 2/0

(2x70)

(2x70)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

1 (50)

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 3/0

(2x70)

(2x95)

(2x95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

350

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 3/0

2 ea. 4/0

(2x70)

(2x95)

(2x95)

(2x120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

1/0 (60)

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

2 ea. 4/0

(2x70)

(2x95)

(2x120)

(2x120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

2/0 (70)

3/0 (95)

4/0 (120)

2 ea. 2/0

2 ea. 3/0

2 ea. 4/0

3 ea. 3/0

3 ea. 3/0

(2x70)

(2x95)

(2x120)

(3x95)

(3x95)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This chart is a general guideline and may not suit all applications. If cables overheat, use next size larger cable.

**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

 

( ) = mm2 for metric use

S-0007-F

***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.