Miller Electric Big Blue 400 KX manual Activating The Dry Charge Battery If Applicable

Models: Big Blue 400 KX

1 72
Download 72 pages 99 b
Page 25
Image 25

5-4. Activating The Dry Charge Battery (If Applicable)

3

2

1

4

5 A For 30 Minutes

OR+

Tools Needed:

30 A For 12 Minutes

 

5-5. Connecting The Battery

YAlways wear a face shield, rubber gloves and protective clothing when working on a battery.

Remove battery from unit.

5Vent Caps

6Sulfuric Acid Electrolyte (1.265 Specific Gravity)

7Well

Fill each cell with electrolyte to bottom of well (maximum).

YDo not overfill battery cells.

Wait ten minutes and check electro- lyte level. If necessary, add electro- lyte to raise to proper level. Reins- tall vent caps.

8 Battery Charger

YRead and follow all instruc- tions supplied with battery charger.

Charge battery for 12 minutes at 30 amperes or 30 minutes at 5 am- peres. Disconnect charging cables and install battery.

.When electrolyte is low, add

only distilled water to cells to maintain proper level.

drybatt1 6/05 − S-0886

.Close door after connecting battery.

Tools Needed: 1/2 in

YConnect Negative (−) Cable Last.

+

Ref. 803 576−C / Ref. 217 358-B / S-0756-C

OM-4423 Page 19

Page 25
Image 25
Miller Electric Big Blue 400 KX manual Activating The Dry Charge Battery If Applicable, Connecting The Battery