Miller Electric Big Blue 502P, Big Blue 402P manual Remote Amperage Control On CC Models Optional

Models: Big Blue 402P

1 82
Download 82 pages 32.48 Kb
Page 29
Image 29
6-3. Remote Amperage Control On CC Models (Optional)

6-3. Remote Amperage Control On CC Models (Optional)

1

Remote Amperage Adjust

1

Receptacle RC13

Connect optional remote control to

RC13 (see Section 5-10).

In Example:

Example: Combination Remote Amperage Control (Stick)Range = 125 to 320 A DC

Percentage Of Range = 50%

Max = About 223 A DC (50% of 125 to 320)

 

 

 

Max (223 A DC)

 

 

 

Min (87 A DC)

Set Switches

Set Range

Set Control

Adjust Optional Remote Control

 

 

 

0774 / Ref. 154 862-A / Ref. 181 711-A / 802 160-D

6-4. Weld Control/Arc Condition Information Label

 

 

 

 

. Set weld controls as shown to

 

 

 

achieve softer or stiffer arc condi-

 

 

 

tions for different applications.

212 944-A

Return To Table Of Contents

OM-491 Page 25

Page 29
Image 29
Miller Electric Big Blue 502P Remote Amperage Control On CC Models Optional, Weld Control/Arc Condition Information Label