SECTION 3 − INSTALLATION
3-1. Specifications
Welding | Input | Rated | Welding | Maximum | Amperes Input At Rated Load |
|
|
| Net | ||||
Mode | Power | Output | Amperage |
| Output, 50/60 Hz |
| KVA | KW | Dimensions | ||||
|
|
| Range | Voltage |
|
|
|
|
| Weight | |||
|
|
| 230 |
| 460 |
| 575 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 250 A @ |
|
|
|
|
|
|
|
|
|
|
|
|
| 30 VDC, |
|
| 30.5 |
| 14.7 |
| 11.6 | 11.7 | 8.6 |
|
|
|
| 50 % Duty |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Cycle | 77 VDC |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |||
| 200 A @ |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 28 VDC, |
|
| 21.7 |
| 11.4 |
| 9.2 | 9.1 | 6.4 | H: |
|
|
| 100 % |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| (343 mm) |
| |
Stick |
| Duty Cycle |
|
|
|
|
|
|
|
|
| 40 lb | |
|
|
|
|
|
|
|
|
|
| W: | |||
|
|
|
|
|
|
|
|
|
|
| |||
(SMAW) |
|
|
|
|
|
|
|
|
|
|
| (191 mm) | (18.2 kg) |
| 200 A @ |
|
|
|
|
|
|
|
|
| |||
|
| 28 VDC, |
|
| 42.6 |
| n/a |
| n/a | 9.8 | 6.5 | D: 18 in (457 |
|
|
| 50 % Duty |
|
|
|
| mm) |
| |||||
| Cycle | 65 VDC |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |||
| 150 A @ |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 26 VDC, |
|
| 30.4 |
| n/a |
| n/a | 6.9 | 4.4 |
|
|
|
| 100 % |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Duty Cycle |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load without overheating.
If unit overheats, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.
Y Exceeding duty cycle can damage unit and void warranty.
206 173
200 A @ 50% Duty Cycle For Single Phase Operation | 250 A @ 50% Duty Cycle For 3 Phase Operation |
5 Minutes Welding | 5 Minutes Resting | 5 Minutes Welding | 5 Minutes Resting |
Overheating |
|
|
|
| 0 | A or V |
|
|
| 15 |
|
|
| OR |
|
| Minutes | Reduce Duty Cycle |
|
|
|
|