3-12. Connecting Input Power
! Turn Off welding power source, and check voltage on input capacitors accord- ing to Section
1 Strain Relief Connector Clamp Obtain and install proper connector.
2 Input And Grounding Conductors
3 Contactor W1
Select size and length using Sec- tion
L1 L2 L3
For Models With Optional Ground Current Sensor:
4 Ground Current Sensor
3
1
Connections For
Standard Model
4
2
Or
When cutting input and ground con- ductors to length, ground conductor must be 26 inches (660 mm) long to wrap around ground current sen- sor. Note that ground conductor must be insulated between strain relief and ground terminal.
Insert input and grounding conduc- tors through strain relief. Route grounding conductor through reed
5switch from right side of unit, under switch, and through reed switch again (two turns total) before con- necting to ground terminal.
For All Models:
| 5 Line Disconnect Device |
L1 | See Section |
L2 | Reinstall right side panel. |
L3 |
|
= GND/PE
! Always connect grounding conductor first.
1 2
|
|
|
| Tools Needed: |
3 | L1 | L2 | L3 |
|
| Connections For |
| 5/16 in | |
Models With Optional |
| |||
Ground Current Sensor | 801 |