4-2. Meter Functions

.The meters display the actual weld output values for approximately three seconds after the arc is broken.

Mode

 

Meter Reading At Idle

 

Meter Reading While Welding

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

MIG

 

24.5

 

 

 

 

 

24.5

 

 

250

 

 

 

Preset Volts

 

Blank

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

Trim

 

V

 

A

Pulsed

 

 

 

 

50

 

 

24.5

 

 

250

 

MIG

 

 

 

 

 

 

 

 

 

 

 

Blank

Pulse Display

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Stick−

 

 

 

 

85

 

 

24.5

 

 

85

 

Contactor Remote

 

 

 

 

 

 

 

 

 

 

 

Blank

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Stick−

 

80.0

 

 

85

 

 

24.5

 

 

85

 

Contactor ON

 

 

 

 

 

 

 

 

 

Actual Volts (OCV)

Preset Amps

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

V

 

A

 

V

 

A

Manual

 

PPS

 

 

200

 

 

24.5

 

 

85

 

Pulse

 

 

 

 

 

 

 

 

 

 

Pulses Per Second

 

Actual Volts

Actual Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

.The Stick mode provides the Adaptive Hot Startfeature, which automatically increases the output amperage at the start of a weld should the start require it. This eliminates electrode sticking at arc start.