Miller Electric OM-234 016D manual Controls For Millermatic 140/180 Models

Models: OM-234 016D

1 48
Download 48 pages 17.17 Kb
Page 21
Image 21

SECTION 4 − OPERATION

4-1. Controls For Millermatic 140/180 Models

A. Spool Gun Operation On Millermatic 140/180 Models

2

1

3

6 5

4

.Spool Gun/MIG Gun switch on Millermatic 140/180 must be in Spool Gun position for spool gun to operate.

1 Shielding Gas Cylinder

For shielding gas connections, see welding power source Owner’s Manual.

2 Valve

Open valve on cylinder just before welding.

Close valve on cylinder when finished welding.

3 Spool Gun/MIG Gun Switch

Switch must be set in Spool Gun position for spool gun to operate.

4 Trigger

Press trigger to energize welding power source contactor, start shielding gas flow, and begin wire feed.

5 Wire Feed Speed Control

Wire feed speed is controlled by welding power source Wire Speed control (see welding power source Owner’s Manual or door chart for appropriate setting).

6 Voltage Control

Arc voltage is controlled by welding power source Voltage control (see welding power source Owner’s Manual or door chart for appropriate setting).

.To purge shielding gas line, set gun selection switch (item 3) to the MIG Gun position. Press spool gun trigger to energize gas valve. Shielding gas will flow, but spool gun will not feed wire. Hold trigger in for several seconds to purge gas line. Return gun selection switch to the Spool Gun position before welding.

sb5.1* 6/92 − S-0621-C / Ref. 802 982-A / 804 986-A

OM-234 016 Page 17

Page 21
Image 21
Miller Electric OM-234 016D Controls For Millermatic 140/180 Models, Spool Gun Operation On Millermatic 140/180 Models