4-9. Installing Alternative Plug

4-9. Installing Alternative Plug

.This procedure is necessary if the unit is to be connected to a 230 VAC receptacle, or to a 115 VAC receptacle that requires a plug that is different from the supplied plug.

.See Section 4-8for instructions on setting changeover switch for proper voltage. 2

3

6

1 7

4

5

Tools Needed:

1 Supplied 115 VAC Plug

Cut cord close to plug.

2Alternative PLug (230 VAC Plug Shown)

3Load 1 (Brass) Terminal

4Load 2 (Brass) Terminal

5Ground (Green) Terminal

6Outer Shell

7Cord Grip

Strip cord jacket back enough to separate conductors. Strip conduc- tors enough to make good contact with plug terminals. Make plug con- nections and reinstall outer shell and cord grip. Tighten assembly screws onto shell. Do not overtighten.