Image 25
6-3. Torch And Work Cable Connections

6-3. Torch And Work Cable Connections

6 8

If torch or work cable needs to be removed or replaced, proceed as follows:

4

7

1 Torch Connections

2 Work Cable Connections

5 6

2

4

3

4

5

3

Turn power Off, and disconnect input power plug from receptacle. Remove wrapper from unit.

Torch Connections

Remove existing torch cable from unit.

1Strain Relief

2Torch Cable

Insert cable through strain relief. Slide strain relief nut onto torch cable, but do not tighten.

3 Air Line Connector

Insert air line connector into solenoid fitting.

4 Plug PLG1/Receptacle RC1

Connect PLG1 from torch to receptacle RC1 on end of wiring harness connected to circuit board PC1.

5Ring Terminal And TORCH RED Terminal

Connect ring terminal on end of red leads to TORCH RED terminal.

6Ring Terminal And TORCH WHITE Terminal

Connect ring terminal on end of white leads to TORCH WHITE terminal.

Tighten strain relief nut.

Tighten strain relief around cable.

Work Cable Connections

Remove existing work cable from unit.

7 Work Cable

.Be sure to allow some work cable slack inside the unit.

Insert work cable with strain relief into front panel.

Tighten strain relief nut. Tighten strain relief around cable.

8 Work Cable Ring Terminal

8

6

5

Tools Needed:

1/4 in

Route cable under center baffle. Connect ring terminal on end of work cable to terminal labeled WORK on circuit board PC1.