Image 27
6-5. Troubleshooting Power Source

6-5. Troubleshooting Power Source

Is input power connected to correct line voltage?

Is input power connected to correct line voltage? Yes

Is Changeover switch S2 in the 115V or 230V position?

fully counterclockwise (see Section 5-1). Check forYes

Does the breaker trip when unit is set on 115V?

No

Is Power switch S1 in the On position?

Manual backgroundYes

Is the cooling fan running?

Manual backgroundYes

Is Power light flashing?

No

No

No

Yes

No

No

Yes

Connect unit to proper input Manual backgroundvoltage (see Section 4-8).

Place Changeover switch in Manual backgroundproper position for input

voltage (see Section 4-8).

Turn down output current. (see Section 5-1).

Place Power switch in the On position. (see Section 5-1).

*

Manual background Check Power switch S1 and relay CR2 and thermistor R1 on PC2. Replace PC2 if R1 or CR2 are not functioning correctly.

*

Reset Power switch S1 and verify line power Manual background voltage (see Section 4-1). Check relay CR2, thermistor R1 on PC2,

and Control board PC1.

Is Cup Status light On or flashing?

Manual background No

Is Temp Status light On?

Manual background No

Is Pressure Status light On or flashing?

Manual backgroundNo

Does pilot arc ignite?

Manual backgroundYes

Does pilot arc

transfer to workpiece?

Manual background Yes

Check all connections, Check main transformer T1, Check boost inductor L1 and buck inductor L2.

Return to beginning of chart.

Yes

Check torch consumables.

 

Reset Power switch S1.

 

 

Yes

If unit is overheated, wait

while fan cools down unit

 

 

temperature.

 

 

*

Turn Output control

fully counterclockwise (see Section 5-1). Check for

Yes gas/air flow at torch. Check

Control board PC1, pressure switch S3 (gauge), air filter, valve AS1, and air supply connection to unit and torch.

Press torch trigger and check if pilot arc ignites. Check torch consumables.

No Manual background*Check torch connections, air filter, pressure switch S3, valve AS1, air supply connection to unit, torch, and PC1.

Place torch near workpiece and check if pilot arc “jumps” No or transfers to workpiece. Manual backgroundCheck work clamp connection. *Check Control board PC1 and connections, and torch and its connections.

*Servicing procedure to be performed only by authorized Service Station.