SECTION 5 − OPERATION

SECTION 5 − OPERATION

5-1. Controls

4

2

3

ON

OFF

5

1

PRESSURE

 

60 PSI

6

20

16 5-1. Controls24

 

 

 

27

 

 

 

 

 

 

Set To

 

Setting Gas/Air Pressure

 

60 PSI (414 kPa)

 

 

 

 

1

20

 

5

 

20

 

 

 

 

16

24

Requires

6

16

24

90-120 PSI

 

 

(621-827 kPa)

 

 

 

 

 

Supply

 

 

 

 

27

 

 

 

27

1 Output Control

Use control to set cutting output.

Place control in Gas/Air Set position to safely adjust gas/air pressure. Only gas/air circuit is activated.

If 22-27 amperes of cutting output is used with 115 VAC input power, and the overload protection on the input power circuit fre- quently opens, either reduce the cutting out-

put and/or the cut time or find more adequate power (see Section 4-1).

2Trouble Lights (See Section 6-2)

3Power Light

4Power Switch

Setting Gas/Air Pressure

5Air Filter/Regulator

6Pressure Adjustment Knob

Place Output control in Gas/Air position and turn on gas/air supply. Lift knob and turn to adjust pressure. Push knob down to lock in setting.

Place Output control in desired cutting output.

.At ambient temperatures below −55 C (235 F), readjustment of gas/air pressure regulator may be necessary.