Register Descriptions

5

Memory Bus A ECC correction/detection enable.

4 Memory Bus B ECC correction/detection enable.

3:0 Double byte parity mask for 128 bits of data.

2.4.2.23PVD_D_FERR: Data on First PVD Parity Error

Bus CBN, Device Number:

04h

 

 

Address Offset:

D0-D7h

Size:

64 bits

Default Value:

0

Attribute:

Read Only, New Value Latched

 

 

 

anytime appropriate FERR register

 

 

 

bit is set

This register records and latches the data associated with the first parity error detected on the PVD bus.

Bits Description

63:0 PVD - Private Data Bus data.

2.4.2.24PVD_PAR_FERR: Parity on First PVD Parity Error

Bus CBN, Device Number:

04h

 

 

Address Offset:

D8h

Size:

8 bits

Default Value:

0

Attribute:

Read Only, New Value Latched

 

 

 

anytime appropriate FERR register

 

 

 

bit is set

This register records and latches the data associated with the first parity error detected on the PVD bus.

Bits Description

7:4 reserved(0)

3:0 Double–byte parity of error

2.4.2.25PVD_TXINFO_FERR: TXINFO on First PVD Parity Error

Bus CBN, Device Number:

04h

 

 

Address Offset:

D9-DAh

Size:

16 bits

Default Value:

00h

Attribute:

Read Only, New Value Latched

 

 

 

anytime appropriate FERR register

 

 

 

bit is set

This register records the ITID and failing chunk corresponding to the first double-byte parity detected by private bus interface in the SDC.

Bits Description

15:9 reserved(0)

8:6 DC - Data Chunk of ITID.

5:0 ITID - ITID of error.

Intel® 460GX Chipset Software Developer’s Manual

2-19

Page 39
Image 39
Intel 460GX manual Pvddferr Data on First PVD Parity Error, Pvdparferr Parity on First PVD Parity Error