Register Descriptions

Bits Description

7Disable

This bit can be written by software. When set, the ITID is retired immediately and not captured. Therefore there can be no checking of the address. See Section 6 for the usage of this bit.

6Valid

If set then the ITID in bits 5:0 is valid and shows the address of a single-bit memory error. Writing a 1 to this bit will clear the ITID and reset the valid bit.

5:0 ITID

The ITID of the SEC error. These bits are read-only.

2.4.1.2

DEDTID: DED ITID

 

 

 

 

Bus CBN, Device Number:

00h

Function:

0

 

Address Offset:

81h

Size:

8 bits

 

Default Value:

00h

Attribute:

Read Only/Write

 

 

 

 

Clear, Read/Write

 

Sticky:

Yes

Locked:

No

This register is used to capture the ITID for a double bit memory ECC error. The ITID can then be used to determine the address of the failure. To force the ITID to be cleared and re-used, write a 1 to bit 6. This register is set anytime that the DED bit is sent from the SDC to the SAC on a ‘Retire ITID’ command.

Bits Description

7Disable

This bit can be written by software. When set, the ITID is retired immediately and not captured. Therefore there can be no checking of the address. See Section 6 for the usage of this bit.

6Valid

If set then the ITID in bits 5:0 is valid and shows the address of a double-bit memory error. Writing a 1 to this bit will clear the ITID and reset the valid bit.

5:0 ITID

The ITID of the double-bit error. These bits are read-only.

2.4.1.3

FSETID: FSE ITID

 

 

 

 

Bus CBN, Device Number:

00h

Function:

0

 

Address Offset:

82h

Size:

8 bits

 

Default Value:

00h

Attribute:

Read Only/Write

 

 

 

 

Clear, Read/Write

 

Sticky:

Yes

Locked:

No

This register is used to capture the ITID for a system bus data error. The ITID can then be used to determine the address of the failure. To force the ITID to be cleared and re-used, write a 1 to bit 6. This register is set anytime that the ADE bit is asserted and both SEC and DED are deasserted on a ’Retire ITID’ command from the SDC to the SAC. NOTE: this register is set for both processor- bus errors and errors on the SAC-to-SDC data bus.

2-6

Intel® 460GX Chipset Software Developer’s Manual