Miller Electric SS-75S12, SS-75S16, SS-75D12, and SS-75D16 Power Switch, Jog/Purge And Trigger Hold

Models: SS-75D12 SS-75S12 SS-75S16 and SS-75D16

1 44
Download 44 pages 19.24 Kb
Page 25
Image 25

5-2. Power Switch

1 Power Switch

1

803 153

5-3. Jog/Purge And Trigger Hold

1 Jog/Purge Push Button

3

2

1

Pressing the Jog/Purge switch al- lows the operator to jog wire without energizing the weld power or gas valve circuit.

Jog speed can be adjusted with the Wire Speed control when the unit is jogging wire. If equipped with meters, the unit displays jog speed while the unit is being jogged.

Pressing the Jog/Purge button also allows the operator to purge gas lines before welding and to preset gas pressure at the regu- lator.

2 Trigger Hold Switch

Trigger hold allows the operator to weld without holding the gun trigger.

To use the trigger hold function, place the trigger hold switch in the On position.

The operator must hold the trig- ger for a minimum of 2 seconds, but not longer than 6 seconds be- fore releasing it. Welding will con- tinue when the trigger is released.

To stop welding, press the trigger again.

3 Wire Speed Control

803 152

OM-230 298 Page 21

Page 25
Image 25
Miller Electric SS-75S12, SS-75S16, SS-75D12, and SS-75D16 manual Power Switch, Jog/Purge And Trigger Hold