Miller Electric WC-115A manual Overload Protection, Troubleshooting

Models: WC-115A

1 28
Download 28 pages 26.02 Kb
Page 22
Image 22

5-1.

Overload Protection

 

 

 

 

 

 

If fuse F1 opens, the weld control

 

 

 

shuts down. To check or change

 

1

2

F1, proceed as follows:

 

1

Fuse Holder Cover

 

 

 

 

 

 

2 Fuse (See Parts List For Fuse

 

 

 

 

Size)

 

Push And Turn

Pull Out And

Push And Turn

 

 

 

Replace F1

 

 

 

 

 

 

Ref. 144 451-D / Ref. 800 185-A

5-2.

Troubleshooting

 

 

 

Trouble

Remedy

 

 

Pressing gun trigger does not energize

Secure plug PLG4 in 115 volts ac receptacle (see Sections 3-7and 3-8).

weld control or welding wire.

 

 

 

 

Secure gun plug in Gun Control receptacle RC3 on weld control (see Section 3-4).

Check fuse F1 and replace if necessary (see Section 5-1).

 

See Troubleshooting Section of gun and/or welding power source Owner’s Manual.

 

 

For models without optional contactor

Secure plug PLG5 in 14 pin receptacle on welding power source (see Section 3-9).

control: Pressing gun trigger feeds

 

wire but does not energize welding

See Troubleshooting Section of welding power source Owner’s Manual.

wire.

 

 

 

For models with optional contactor

See Troubleshooting Section of welding power source Owner’s Manual. Check contactor visually for

control: Pressing gun trigger feeds

closure.

wire but does not energize welding

 

wire.

 

 

 

Pressing gun trigger energizes wire,

See Troubleshooting Section of gun Owner’s Manual.

but wire does not feed.

 

 

 

Erratic weld output.

Secure plug PLG4 in 115 volts ac receptacle (see Sections 3-7and 3-8).

 

 

 

Secure gun plug in Gun Control receptacle RC3 on weld control (see Section 3-4).

 

 

 

Secure plug PLG5 in 14 pin receptacle on welding power source (see Section 3-9).

See Troubleshooting Section of gun and/or welding power source Owner’s Manual.

Wire feeds erratically.

See Troubleshooting Section of gun Owner’s Manual.

 

 

Wire feed speed does not switch from

Check reed relay, and replace if necessary. Check that weld cable is routed through reed relay.

run-in speed to weld wire feed speed.

 

 

 

Wire feeds, but burns back.

Readjust ramp-up speed potentiometer R70 on motor control board PC1 (see Section 3-5).

 

 

No gas flow.

Check gas hose and connections, and replace if necessary (see Section 3-4).

 

 

Wire does not feed, and is not

Connect voltage sensing lead to workpiece (see Section 3-5).

energized on CC welding power

 

sources.

 

OM-1078 Page 18