3-6. Circuit Protection

1 Circuit Breaker CB1

Circuit breaker CB1 is located in- side the wire feeder as shown.

CB1 Protects the auxiliary 24 volt AC circuit from overload.

1

3-7. Connecting Wire Feeder to Power Source

1

2

3

4

7 5 6

5 4

1

2

Make connections as shown. Be sure connections are tight.

114 Pin Control Cord

2Weld Cable (see Section 3-8for connection inside wire feeder)

3Gas Hose

Connect hose to feeder using sup- plied clamp. Connect other end of gas hose to the power source gas cylinder or gas circuit.

4Blue Quick Connect Fitting (Coolant Output to Gun)

Connect blue to blue and red to red.

5Red Quick Connect Fitting (Coolant Return From Gun)

Connect blue to blue and red to red.

6Work Cable Clamp (see Section 3-8)

7Cable Bundle Collar (see Section 3-8)

OM-223 839 Page 9

Page 13
Image 13
Miller Electric XMS 44 owner manual Circuit Protection, Connecting Wire Feeder to Power Source