Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your

dealer.

POWER indicator STATUS indicator

Normal condition

POWER

STATUS

CONDITION

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stand-by

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

Off

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp stand-by (about 1 minute)

The POWER button cannot be used to

Steady

Blinking

 

switch between on and off.

green

green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The power is on. (Normal condition)

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Steady

 

 

 

green

green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal condition

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

Steady

green

or

Blinking orange

Abnormal temperature

 

 

• The ventilation grilles are clogged with dust or dirt.

Clean the ventilation grilles.

• The room temperature is high.

Relocate the projector to a cooler place.

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The protection circuit is working or the lamp is in an

• Wait until the STATUS indicator goes out,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

abnormal condition.

then press the POWER button.

Blinking green

 

• If the above solution is not effective, replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

Replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Blinking green/red

reached 2250 hours*1 while the power was on.)

Change with a new lamp if this problem

 

green

 

 

 

 

 

 

 

 

 

 

 

recurs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

Blinking red

reached 2250 hours*1 while the power was off.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

Steady red

reached 3000 hours*1*2 while the power was off.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal.

Contact your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

 

Blinking

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

green/red

 

Blinking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1 Duration when LAMP MODE of the INSTALLATION menu is set to LOW. When it is set to STANDARD, this duration will be shorted.

*2 Duration when LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.

EN-36

Page 36
Image 36
Mitsubishi HC1100 user manual Indicators, Normal condition, Abnormal condition, Status Condition