(7)Damper Operation Mode
During damper operation mode, the damper is forcibly opened and closed and the state of damper is shown on the panel.
1Setting
●With the ice making compartment door left open, simultaneously press and for about 3 seconds until a “beep” sound is heard, and “88” blinks.
●With the door left open, simultaneously press | and | for about 3 seconds until a “beep” sound is heard. |
2Status display of each damper
Each compartment display turns on when each damper is open and turns off when each damper is closed. Ex.) When all dampers are open;
Refrigerator compartment
Ice making compartment
Versa compartment Freezer compartment
REFCHILL VR
FZR
Slide chilled compartment
3How to make each damper open or close
Although the state is shown on the panel, check airflow and confirm the damper is really opened or closed. However, air does not come out when the door is closed, so put a magnet on the door switch to simulate the condition of the door closed.
●Change of display
Kind of damper
Refrigerator Slide chilled Ice making | Versa | Freezer |
compartment compartment compartment compartment compartment |
(Ex.) When making the damper of refrigerator compartment open
TEMP
Display
(R)
(C)
(I)
(S)
(F)
(1)Press to select the damper to be set up.
A “beep” sound is heard and the kind of damper is changed every time
Refrigerator compartment | Slide chilled compartment |
Versa compartment | Freezer compartment |
(1)Damper to | (2)"p " to open, |
be set up | " " to close |
is pressed. |
|
Ice making compartment |
|
(2)Press to “0” to open the damper or “ ” to close the damper.
(3)Press | for about 3 seconds to convey the setting to the damper. | As the damper of slide chilled compartment opens and | |||||
A“beep”sound is heard if the setting has been conveyed. | closes in conjunction with the damper of refrigerator | ||||||
compartment, it is necessary to set them to the either | |||||||
After the setting is conveyed, the damper starts operating | of the following. |
|
|
| |||
and the display blinks. It stops blinking and starts to light |
|
| How to set |
| |||
when the operation stops automatically. Please note that the |
|
|
|
|
| ||
Open | Open | Set | to 0 and then set | to 0. | |||
setting cannot be changed when the damper is operating. | |||||||
Close | Open | Not available |
| ||||
|
|
| |||||
|
|
|
|
|
|
| |
|
| Open | Close | Set | to 0 and then set | to . | |
|
|
|
|
|
|
| |
|
| Close | Close | Set | to . |
| |
|
|
|
|
|
|
|
4 Release |
|
|
●With the door of ice making compartment left open, simultaneously press | and | for about 3 seconds until a |
“beep” sound is heard. The screen returns to the temperature display. |
|
|
●This function is not automatically released. |
|
|
●Follow the procedure above to release this function. For the prevention of the compressor, avoid releasing it by plugging and unplugging the power cord.
12