6-6 TROUBLE CRITERION OF MAIN PARTS MR-G50J-NZ
Components/ |
|
| Check Method and Criterion |
|
|
|
| Parts Mounted | ||||
Part Name |
|
|
|
|
|
| Position | |||||
|
|
|
|
|
|
|
|
|
|
| ||
Compressor | Black |
| Model |
|
| ETI100E13DAH |
| In the machine | ||||
|
|
|
|
| chamber at the | |||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Rated input | W | 45/159 (1620/4800rpm) |
| rear side of the | |||||
|
|
|
| frame. | ||||||||
|
|
| Starting current | A |
|
| 2.0 |
| ||||
|
|
|
|
|
|
| ||||||
White |
| Running current | A | 0.03/2.19 (1620/4800rpm) |
|
| ||||||
Red |
|
|
|
|
| Abnormal |
|
| ||||
|
|
|
|
|
| Normal |
|
| ||||
|
|
|
|
|
| (faulty) |
|
| ||||
|
|
|
|
|
|
|
|
|
| |||
Measure the resistance |
| Winding |
|
| Open (∞ ' ) |
|
| |||||
with a tester. |
|
| 9.3 ' |
|
| |||||||
|
|
| or |
|
| |||||||
|
|
|
|
|
|
| ||||||
|
|
| (20:) | short circuit |
|
| ||||||
|
|
|
|
|
| (0' ) |
|
| ||||
Motor | Model |
|
|
|
|
|
| In the machine | ||||
protector |
|
|
|
|
|
| chamber at the | |||||
|
|
|
|
|
|
|
|
|
|
| ||
| Connected Open |
|
| 100 ±50 : or more |
| rear side of the | ||||||
|
|
|
| frame. | ||||||||
| Energize it at 17.0A, 25: for 16 seconds at the longest. | |||||||||||
| point |
|
|
| ||||||||
| Close |
|
|
| 61±8: or less |
|
| |||||
|
|
|
|
|
|
| ||||||
Measure the resistance with a tester. (Ambient temperature : Room temperature) |
| |||||||||||
| Contact point |
|
|
| Normal |
| Abnormal (faulty) |
| ||||
| 1 | 2 |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| Less than 1' |
| Open circuit (∞ ' ) |
| ||||
1 | 2 |
|
|
|
|
|
|
|
|
|
|
|
Refrigerator |
| Model |
|
|
| UDQM002B3 |
|
|
| In the fan grille | ||
fan motor |
|
|
|
| DC brushless |
|
|
| of the freezer | |||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| compartment. | |||
|
| Number of pole |
|
| 10 |
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||||
|
| Diameter |
|
| {150 (Mixed flow fan) |
|
| |||||
Measure the resistance with a tester. (Ambient temperature : Room temperature) |
| |||||||||||
|
|
|
|
|
| Normal |
|
| Abnormal |
|
| |
|
|
|
|
|
|
|
| (faulty) |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Between 1 and 4 (GND and IC | Between 1 and 4 |
| |||||
|
|
|
|
| Power): About 12 k' |
|
| : open circuit (∞ ' ) |
| |||
|
|
|
|
| Between 3 and 4 (Power and |
| Between 3 and 4 |
| ||||
|
|
|
|
| IC Power): ∞ ' |
|
| :short circuit (0' ) |
| |||
|
|
|
|
|
| 4 | IC Power |
|
|
|
|
|
|
|
|
|
|
| 3 | Power |
|
|
|
|
|
|
|
|
|
|
| 2 | FG |
|
|
|
|
|
|
|
|
|
| IC | 1 | GND |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 1 | 2 3 4 : Pin No. |
|
|
|
|
|
|
|
|
| |
Machine |
| Model |
|
|
| UDQM004B3 |
|
|
|
| In the machine | |
chamber fan |
|
|
|
| DC brushless |
|
|
|
| chamber at the | ||
|
|
|
|
|
|
|
|
| ||||
motor |
| Number of pole |
|
|
| 10 |
|
|
|
| rear side of the | |
|
| Diameter |
|
|
| {140 (Extra fan) |
|
|
|
| frame. | |
|
|
|
|
|
|
|
|
|
| |||
|
| Operation method | During compressor operation |
|
| |||||||
Measure the resistance with a tester. (Ambient temperature : Room temperature) |
| |||||||||||
|
|
|
|
|
| Normal |
|
| Abnormal (faulty) |
| ||
|
| 4 | IC Power | Between 1 and 4 (GND and IC | Between 1 and 4 |
| ||||||
|
| 3 | Power |
|
| |||||||
|
| 2 | FG |
| Power): About 9 k' |
|
| : open circuit (∞ | ' ) |
| ||
|
| 1 | GND |
|
|
|
|
|
|
|
|
|
|
| IC |
|
|
|
|
|
|
|
|
|
|
1 2 3 4 | : Pin No. |
|
|
| Between 3 and 4 (Power and | Between 3 and 4 |
| |||||
|
|
|
| IC Power): ∞ ' |
|
| :short circuit (0' ) |
| ||||
|
|
|
|
|
|
|
|
|
26