6. Electrical work
Function table
Select unit number 00
Mode | Settings |
|
| Mode no. | Setting no. Initial setting | setting |
Power failure automatic recovery | Not available |
| 01 | 1 |
| |
| Available | *1 | 2 |
| ||
|
|
|
| |||
Indoor temperature detecting | Indoor unit operating average |
|
|
| 1 |
|
| Set by indoor unit’s remote controller |
| 02 | 2 |
| |
| Remote controller’s internal sensor |
|
|
| 3 |
|
LOSSNAY connectivity | Not Supported |
|
|
| 1 |
|
| Supported (indoor unit is not equipped with | 03 | 2 |
| ||
| Supported (indoor unit is equipped with |
|
| 3 |
| |
Power voltage | 230 V |
| 04 | 1 |
| |
| 208 V |
| 2 |
| ||
|
|
|
|
| ||
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller]) |
|
|
|
|
| |
Mode | Settings |
|
| Mode no. | Setting no. Initial setting | setting |
Filter sign | 100Hr |
|
|
| 1 |
|
| 2500Hr |
| 07 | 2 |
| |
| No fi lter sign indicator |
|
|
| 3 |
|
Fan speed | Silent |
|
|
| 1 |
|
| Standard |
| 08 | 2 |
| |
| High ceiling |
|
|
| 3 |
|
No. of air outlets | 4 directions |
|
|
| 1 |
|
| 3 directions |
| 09 | 2 |
| |
| 2 directions |
|
|
| 3 |
|
Installed options | Not supported |
|
| 10 | 1 |
|
| Supported |
|
| 2 |
| |
|
|
|
|
| ||
Up/down vane setting | Equipped with vanes (vanes angle setup | ) |
|
| 1 |
|
| Equipped with vanes (vanes angle setup | ) |
| 11 | 2 |
|
| Equipped with vanes (vanes angle setup | ) |
|
| 3 |
|
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
6.3.3How to set the fixed up/down air direction (Only for wired remote controller and
•Only the particular outlet can be fixed to certain direction with the procedures below. Once fi xed, only the set outlet is fi xed every time air conditioner is turned on. (Other outlets follow UP/DOWN air direction setting of the remote controller.)
Explanation of word
•"Refrigerant address No." and "Unit No." are the numbers given to each air conditioner.
•"Outlet No." is the number given to each outlet of air conditioner.
Horizontal airflow
Remote controller setting The airflow direction of
this outlet is controlled by the airflow direction setting of remote contoller.
Downward
Fixed setting
The airflow direction of this outlet is fixed
in particular direction.
When it is cold because of direct airflow, the airflow direction can be fixed horizontally to avoid direct airflow.
(Refer to the right.)
• "Up/Down air direction" is the direction (angle) to fi x.
Reset | 1 | 2 | 3 | 4 | 5 |
| horizontal |
|
|
|
|
Outlet No.3 | Outlet No.4 |
MITSUBISHI
ELECTRIC
label
Outlet No.2 | Outlet No.1 |
Note: "0" indicates all outlets. |
|
10