7. Test run
• If the unit cannot be operated properly after the test run has been performed, refer to the following table to remove the cause.
|
| Symptom |
|
| Cause | |
| Wired remote controller | LED 1, 2 (PCB in outdoor unit | ||||
|
| |||||
|
| For about 2 minutes | After LED 1, 2 are lighted, LED 2 is turned | •For about 2 minutes after | ||
PLEASE WAIT |
| off, then only LED 1 is lighted. (Correct | controller is not possible due to system | |||
| after | |||||
|
| operation) |
| operation) | ||
|
|
|
| |||
|
|
|
|
| •Connector for the outdoor unit’s protection device is not | |
PLEASE WAIT | Error code |
| Only LED 1 is lighted. | LED 1, 2 blink. | connected. | |
| Reverse or open phase wiring for the outdoor unit’s power | |||||
|
| Subsequent to about |
|
| ||
|
|
|
| terminal block (L1, L2, GR) | ||
|
| 2 minutes after power- |
|
| ||
Display messages do not appear |
|
| • Incorrect wiring between indoor and outdoor units (incorrect | |||
on |
|
| ||||
even when operation switch is | Only LED 1 is lighted. | LED 1 blinks | ||||
| polarity of S1, S2, S3) | |||||
turned ON |
|
| twice, LED 2 blinks once. |
| ||
|
|
| •Remote controller wire short | |||
(operation lamp does not light up). |
|
|
| |||
|
|
|
|
On the wireless remote controller with condition above, following phenomena take place.
•No signals from the remote controller are accepted.
•Operation lamp is blinking.
•The buzzer makes a short ping sound.
Note:
Operation is not possible for about 30 seconds after cancellation of function selection. (Correct operation)
For description of each LED (LED1, 2, 3) provided on the indoor controller, refer to the following table.
LED 1 | (power for microcomputer) | Indicates whether control power is supplied. Make sure that this LED is always lit. |
LED 2 | (power for remote controller) | Indicates whether power is supplied to the remote controller. This LED lights only in the case of the |
|
| indoor unit which is connected to the outdoor unit refrigerant address “0”. |
LED 3 | (communication between indoor and outdoor units) | Indicates state of communication between the indoor and outdoor units. Make sure that this LED is |
|
| always blinking. |
|
|
|
Water supply pump
Water (about 1000cc, 1/4 gal)
Drain plug
Pour water through outlet
.Be carefule not to spray water into the drain pump mechanism.
7.4. Check of drainage (Fig. 7-5)
•Ensure that the water is being properly drained out and that no water is leaking from joints.
When electric work is completed.
. Pour water during cooling operation and check.
When electric work is not completed.
. Pour water during emergency operation and check.
*Drain pan and fan are activated simultaneously when single phase
Be sure to turn it back to the former state after work.