Monessen Hearth DEB30 manual CLEARANCES and HEIGHT REQUIREMENTS, Measuring Heat Resistant Material

Models: DEB20 DEB30

1 40
Download 40 pages 19.41 Kb
Page 13
Image 13
CLEARANCES and HEIGHT REQUIREMENTS

CLEARANCES and HEIGHT REQUIREMENTS

Heat resistant material (minimum requirements) with no wooden mantel or other combustible projection:

To install the gas logs into a fireplace with no wooden mantel, shelf or other combustible projection above the fireplace opening, measure the heat resistant material height, per Figure 5, then see TABLE A.

Heat resistant materials such as slate and marble must be at least 1/2” thick. Sheet metal should not be installed onto combustible material.

IMPORTANT: If you cannot meet these minimum clearances you must operate the heater with chimney flue damper open. Refer to “Installing Vented Applications” found on page 18.

Heat

Resistant

Material

Measure

this

distance

Heater in

Fireplace or

Firebox

Figure 5 - Measuring Heat Resistant Material

HEAT RESISTANT

REQUIREMENTS FOR SAFE INSTALLATION

MATERIAL

 

 

 

 

MEASUREMENT

DEB20

DEB24 and DEB30

 

 

 

12" or more

Hood not required.

Hood not required.

 

 

 

8" to less than 12"

Hood not required.

Extend heat resistent material to 12"

 

 

or install hood. See Figure 5.

 

 

 

Less than 8"

Extend heat resistant

Extend heat resistant material to at

 

material to at least 8"

least 8" and install hood. See Figure

 

and install hood.

5. OR, extend heat resistant mater-

 

See Figure 5.

ial to a height of at least 12".

 

 

 

TABLE A - Heat Resistant Material Requirements with no Mantel or Combustible Projection