ELECTRICAL WIRING
OPERATION OF THERMOSTAT SENSOR
1.Follow millivolt lighting instructions on lighting plate attached to unit or in homeowner’s manual.
2.With control knob in the “ON” position make sure the ON/OFF switch is in the “OFF” position. See Figure 24.
3.The unit is now being controlled by the thermostat sensor. The sensor will now cycle the burners on and off. You can adjust how often the unit cycles by turning the control knob on the sensor.
ON/OFF
Switch
Control
Knob
THE
SERMOS
TTINGTAT
HIGH
2 |
|
6D33 |
|
17 | LOW |
|
Sensor
Figure 24 - Control Knob in “ON” Position and ON/OFF Switch in “OFF” Position
CHECKING SYSTEM OPERATION
The
|
| CONNECT |
|
|
|
CHECK | TO | METER | THERMOSTAT | METER |
|
TEST | TEST | LEADS TO | CONTACTS | READING |
|
|
| TERMINALS |
| SHOULD BE |
|
A | COMPLETE | TP/TH and TH | CLOSED | MINIMUM |
|
| SYSTEM |
|
| 175 |
|
|
|
|
|
|
|
B | THERMOPILE | TP and TP/TH | OPEN | MINIMUM |
|
| OUTPUT |
|
| 500 |
|
|
|
|
|
|
|
A.COMPLETE MILLI-VOLT SYSTEM CHECK
(“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON)
a.If the reading is more than 175
b.If the closed circuit reading (“A” reading) is less than 175
B.Thermopile Output Reading Check
(“B” Reading - Thermostat contacts OPEN - Main burner OFF)
1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 500