ELECTRICAL WIRING (MILLI-VOLT)

ELECTRICAL WIRING (MILLI-VOLT)

The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO OPER-

ATE.

CAUTION

Label all wires prior to disconnection

operation after servicing.

 

when servicing controls. Wiring

 

errors can cause improper and

 

dangerous operation. Verify proper

 

 

Wall

Switch

On/Off

Switch

TH = 3

TP = 1

TP/TH = 2

ODS

Pilot

On/Off

Switch

ODS

Pilot

Milli-volt

Valve

Spade

Terminal

Switch

Optional Wall

Figure 18 - Wiring DiagramSwitch, Remote

Receiver or

CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT

Optional T-Stat

1.Use 18 awg, two-wire cable, 15 feet maximum length.

2.At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of the unit. The color of the wires does not matter.