Monessen Hearth DEB30, DEB20 manual Floor Clearance, Heater in Fireplace or Firebox Combustible

Models: DEB20 DEB30

1 40
Download 40 pages 19.41 Kb
Page 17
Image 17
FLOOR CLEARANCE

FLOOR CLEARANCE

The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top surface of carpeting, tile, etc. See Figure 11.

OR,

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or marble is installed between the base of the fireplace and the combustible flooring. See Figure 12.

Heater in

Fireplace or

Firebox

Combustible

Material

5" Minimum

Figure 11 - Minimum Clearance above Combustible Flooring

This Distance May Now Be Less than 5"

Heater in

Fireplace or

Firebox

Combustible

Material

Heater in14" Minimum MaterialThis Distance May Now Be Less than 5"

Figure 12 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace

44D0060

17

Page 17
Image 17
Monessen Hearth DEB30 Floor Clearance, Heater in Fireplace or Firebox Combustible, Material 5 Minimum, Material 14 Minimum