Monessen Hearth DIS33G manual Milli-Volt/Thermostatcontrol, Lighting Instructions

Models: DIS33G

1 40
Download 40 pages 27.71 Kb
Page 29
Image 29
MILLI-VOLT/THERMOSTAT CONTROL

OPERATING INSTRUCTIONS

MILLI-VOLT/THERMOSTAT CONTROL

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,” page 30.

4.Turn gas control knob clockwise LIGHTING INSTRUCTIONS to the OFF position and turn ON/OFF switch to OFF position.

5.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.

6.From OFF position, turn the gas control knob counterclockwise TO TURN OFF GAS TO HEATER to IGN position. Push in control knob for 5 seconds. NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7.With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.

8.Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise Manual background to the ON position.

10.After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position or adjust thermostat to desired setting.

11.If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” below and call your service technician or gas supplier.

On/Off Switch

Hi/Lo Control Manual backgroundManual backgroundManual backgroundManual backgroundManual background

Ignitor Pilot Control

Piezo Manual background

Figure 35 - Pilot

Figure 36 - Control Cover Plate for Milli-Volt

TO TURN OFF GAS TO HEATER

1.Turn control knob clockwise Manual background to OFF position to completely shut off the heater.

2.If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.

3.If applicable: Turn off all electric power to the heater.

23D8020

29

Page 29
Image 29
Monessen Hearth DIS33G manual Milli-Volt/Thermostatcontrol, Lighting Instructions, To Turn Off Gas To Heater