Monessen Hearth DIS33G CONNECTING REMOTE RECEIVER Figure, Electrical Wiring Milli-Volt, Cover

Models: DIS33G

1 40
Download 40 pages 27.71 Kb
Page 20
Image 20
CONNECTING REMOTE RECEIVER (Figure 21)

ELECTRICAL WIRING (MILLI-VOLT)

CONNECTING REMOTE RECEIVER (Figure 21)

THESE INSTRUCTIONS SUPERCEDE THE SECTION

ENTITLED “HEARTH MOUNT” IN THE MILLI-VOLT

HAND-HELD REMOTE INSTRUCTIONS SUPPLIED

WITH THE REMOTE.

1. Remove cover on control panel to show opening for remote Remote

receiver.Receiver

2. Connect the remote connectors located in the unit.

3.Slide remote receiver in the opening of control panel. Use two screws provided to attach remote receiver to the control panel.

4.Replace Cover.

Cover
NOTE: Do not place remote in combustion chamber.
Figure 21 - Installing Remote Receiver

CHECKING SYSTEM OPERATION

The milli-volt system and individual com- ponents may be checked with a milli-volt meter having a 0-1000 mV range. Conduct each check shown in chart below by con- nection meter test leads to terminals as indicated.

 

 

CONNECT

 

 

 

 

 

METER

SWITCH OR

METER

 

CHECK

TO

LEADS TO

THERMOSTAT

READING

 

TEST

TEST

TERMINALS

CONTACTS

SHOULD BE

 

A

COMPLETE

2 & 3

CLOSED

CLOSED

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

B

THERMOPILE

1 & 2

OPEN

OPEN

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

A. COMPLETE MILLIVOLT SYSTEM CHECK

(“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should turn ON)

a.If the reading is more than 100 milli-volts and the automatic valve still does not come on, replace the control.

b.If the closed circuit reading (“A” reading) is less than 100 millivolts, determine cause for low reading, proceed to Section B below.

B. Thermopile Output Reading Check

(“B” Reading - Thermostat contacts OPEN - Main burner OFF)

1.Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 325 millivolts minimum. If the minimum milli-volt reading is not obtainable, replace pilot.