Monessen Hearth ILDV30NV manual Check Gas Pressure, Do not use open flame to, check for gas leaks

Models: ILDV20PV ILDV30NV ILDV20NV

1 40
Download 40 pages 3.48 Kb
Page 19
Image 19
CHECK GAS PRESSURE

CHECK GAS PRESSURE

ILDV20/ILDV30 Fireplace Insert

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.Install and attach flex line provided with on this appliance to 1/2" gas line.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a soap and water solution or a gas sniffer.

4.To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.

5.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Figure 14. After taking pressure reading, be sure and turn captured screw clock- wise firmly to reseal. Do not over torque. Check test points for gas leaks with a soap and water solution or an electronic gas leak detector.

 

WARNING

Do not use open flame to

 

 

 

 

check for gas leaks.

 

 

 

Pressure

Test "IN"

Pressure Test "OUT"

HI/LO Knob

Pilot Adjustment Screw

 

Figure 14

Gas Pressure Check at Gas Valve

FP1932

83D0511

19