ILDV20/ILDV30 Fireplace Insert

BLOWER REMOVAL and ASSEMBLY

BLOWER REPLACEMENT

Turn off the unit and allow to cool completely. Turn off gas at shut-off and disconnect all electricity to unit.

1.Remove the decorative filigree by gently pulling it out.

2.Rotate the cam on the glass toward the center.

3.Tilt the glass out left and release it from the track.

4.Set the glass on a towel out of the way.

5.Remove the logs and bricks. To remove the brick, unfasten the brackets located on the right and left.

6.Unfasten the brick support plate fastened to the burner.

7.Unfasten the rectangular plate located at the rear of the firebox by only removing the six

(6) screws around the perimeter of the plate.

8.Lift the plate up and slide to the left. You may have to rotate the plate to clear the blower through the hole.

9.Disconnect the two (2) wires to free the blower.

10.Reassemble the blower in reverse order.

Brick Retainers

Brick Panels

Blower Assembly

FP1963

Glass Door Assem- bly

Figure 35

Blower Removal and Assembly

30

83D0511

Page 30
Image 30
Monessen Hearth ILDV20NV, ILDV30NV, ILDV20PV manual Blower Replacement