ILDV20/ILDV30 Fireplace Insert

pRE-INSTALLATION INFORMATION

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installation must be in accor- dance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdic- tion.

In Canada, please consult provincial and/or local authorities having jurisdiction for installation at elevations above 4,500 feet (1,370 m).

ORIFICE SIZES, PRESSURES AND BTUs

Natural Gas

 

Propane Gas

 

Manifold Press: (w.c.)

3.5"

Manifold Press: (w.c.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4.5"

Minimum Supply Pressure

11"

Model Number

ILDV20NV

ILDV20PV

ILDV30NV

ILDV30PV

Gas Type

Natural

Propane

Natural

Propane

Max. BTU/hr Input

20,000

20,000

30,000

30,000

Min. BTU/hr Input

13,000

16,000

20,500

23,000

Orifice Size (as shipped)

#44

1.35 mm

#37

#51

NOTE: The ILDV Series fireplace inserts work without any electrical supply. The blower must be attached to 110/120V AC.

Before You Start

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all con- tents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.

83D0511

Page 6
Image 6
Monessen Hearth ILDV20NV, ILDV30NV, ILDV20PV manual High Elevations, Orifice SIZES, Pressures and BTUs, Before You Start