TROUBLESHOOTING
GENERAL TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | ACTION | |||
|
|
|
| ||
1. | Glass Soots | A. Flame impingement on logs | A. Install log set per instructions. | ||
|
|
|
|
| Inspect the injector and air intake area. |
|
|
|
|
| Make sure this area does not have any blockage from debris |
|
|
|
|
| and clean. |
|
|
|
|
| Check gas supply |
2. | Poor draft due | A. | Too much offset. | A. Reduce offset and/or raise termination.B. | |
| to venting |
|
|
| If thermocouple is producing more than 15 mV, replace |
|
|
|
|
| faulty valve. |
|
| B. Too many elbows | B. Reduce number of elbows | ||
|
| C. Vent height too short | C. | Raise vent | |
|
| D. | Vent too close to roof line | D. | Raise vent |
|
| E. Blockage is restricting venting | E. Remove blockage | ||
|
|
| capacity |
|
|
|
| F. | Incorrect vent type | F. Replace with proper | |
|
| G. | Venting has been constructed with | G. | Replace with proper size |
|
|
| too large or too small vent. |
|
|
|
| H. More than one appliance is using | H. | Construct a single venting system for each appliance | |
|
|
| one venting system. |
|
|
3. | Poor draft due | A. | Cap obstructed by a decorative | A. | Remove or open enclosure or raise cap above it.. |
| to termination |
| enclosure. |
|
|
| cap. | B. | Cap is crushed, damaged or miss- | B. | Replace cap |
|
|
| ing. |
|
|
4. | Poor draft due | A. | Buildings, trees, roof lines inter- | A. Maintain proper clearances and heights to external obstructions; | |
| to ext. environ- |
| fering with venting. |
| Beware of overhangs. |
| ment. | B. | Wind | B. Use cap designed for high winds; raise venting height. | |
|
| C. Vent exposed to cold chase. | C. | Insulate chase. | |
|
| D. Vent exposed to cold weather. | D. Enclose vent within home. | ||
5. | Poor draft due | A. | Negative air pressure. | A. To test for negative air pressure, open a window in the room | |
| to internal |
|
|
| with the fireplace to see if the unit starts drafting correctly. |
| environment.n |
|
|
| Make sure the damper system is in the open position. |
|
|
|
|
| |
6. | Unit shuts | A. | Blockage or restriction in venting. | A. Check for and remove blockage and light pilot following light- | |
| down prema- |
|
|
| ing instructions. |
| turely. |
|
|
|
|