Monessen Hearth BBV400 Vent Installation, Installation Planning, “B” Vent Pipe, B-Ventpipe Sizing

Models: SBV400 BBV400 SBV500

1 42
Download 42 pages 53.86 Kb
Page 14
Image 14
INSTALLATION PLANNING

VENT INSTALLATION

INSTALLATION PLANNING

“B” VENT PIPE

See venting installation instructions provided by the B-Vent manufacturer.

Note: This APPLIANCE MUST BE INSTALLED using “B” vent type pipe that has been listed by a nationally recognized testing agency.

See B-Vent Pipe Sizing chart for proper elbow offset runs.

B-VENT PIPE SIZING

BBV400/400BBV

SBV400/400SBV

SBV500/500SBV

 

 

 

4"

6"

6"

Locate chimney center line dimension from a combustible back wall. See Figures 3 and 4, page 9.

Minimum vertical chimney height - 8'

Minimum height with two (2) 90° elbows - 8'

Elbow requirements allow a maximum of two (2) 90° elbows or four (4) 45° elbows per installation.

Note: Two (2) 45° elbows = One (1) 90° elbow

Horizontal run must never exceed 50% of the height of the vent system.

14

62D4036

Page 14
Image 14
Monessen Hearth SBV400 manual Vent Installation, Installation Planning, “B” Vent Pipe, B-Ventpipe Sizing, BBV400/400BBV