Monessen Hearth SBV400 Electrical Installation, Electrical Wiring, Remote Wall Mounted Switch

Models: SBV400 BBV400 SBV500

1 42
Download 42 pages 53.86 Kb
Page 21
Image 21
ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION

ELECTRICAL WIRING

CAUTION WARNINGELECTRICAL WIRING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc- tion box at the desired location on the wall. See Figure 19. Do not extend beyond the wall switch wire length provided.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

PILOT

 

HI

OFF

ON

TH

 

 

 

 

TP

 

 

TH/TP

 

 

 

WARNING

Do not connect

 

 

 

 

wall switch

 

 

to AC (110V)

 

 

circuit.

 

 

 

 

 

OPTIONAL REMOTE

 

 

WALL SWITCH

 

SPILL

ON

 

SWITCH

 

ON

RS

OFF

 

OFF

 

 

 

 

OPTIONAL REMOTE

 

 

WALL SWITCH

 

 

ON

 

 

OFF

Figure 19 - Wiring Diagram for Wall Switch

62D4036

21

Page 21
Image 21
Monessen Hearth SBV400 Electrical Installation, Electrical Wiring, Remote Wall Mounted Switch, Do not connect, wall switch