Hardware Preparation and Installation

2Configuration Switches

The location of the switches, connectors, and LED indicators on the MVME197LE is illustrated in Figure 2-1. The MVME197LE has been factory tested and is shipped with factory switch settings that are described in the following sections. The MVME197LE operates with its required and factory- installed Debug Monitor, MVME197Bug (197Bug), with these factory switch setting.

Configuration Switch S1: General Information

Switch S1 is a bank of nine two-way switch segments. The following illustration shows the factory configuration of switch S1. The bit values are read as a one when the switch is OFF (open), and as a zero when the switch is ON (closed). The default value for switch S1 is shown below.

Switch S1

O N

1 2 3 4 5 6 7

8 9

CLOSED

OPEN

System Controller (SCON)

General Purpose Input 7 (GPI7)

General Purpose Input 6 (GPI6)

General Purpose Input 5 (GPI5)

General Purpose Input 4 (GPI4)

General Purpose Input 3 (GPI3)

General Purpose Input 2 (GPI2)

General Purpose Input 1 (GPI1)

General Purpose Input 0 (GPI0)

(FACTORY CONFIGURATION)

2-4

Installation Guide

Page 36
Image 36
Motorola MVME197LE manual Configuration Switches, Configuration Switch S1 General Information